0

Out of 0 Ratings

Owner's of the Ashly Chipper NOT FOUND gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 12
 
Operator Manual – CLX-52 Compressor/Limiter Page - 7
All Rights Reserved
CLX-52 Rear Panel
1. Inputs and Outputs - Your CLX
Compressor/Limiter is provided with three
different connector types. 1/4" TRS (tip-ring-
sleeve) jacks, XLR connectors and Euroblocks.
Inputs are 20K active balanced using 1%
metal film resistors, outputs are 132 servo-
balanced.
2. Detector Loop – Ducking - The CLX
Compressor/Limiters have a TRS Insert
DETECTOR PATCH point which can be used
as a "ducking" input, or in conjunction with an
equalizer to produce frequency-sensitive
limiting. Various uses of the detector patch are
discussed under Typical Applications.
3. Power – Switches the unit power on or off.
Installation
Use four screws and washers when rack mounting the unit. For mobile use, the unit should
be further secured as appropriate.
General Requirements
The CLX-52 has specific physical, electrical and signal requirements for proper operation.
These requirements will vary depending on your specific application, setup, and the
settings on the unit. When setting up and testing your system, please take special care to
double check all connections and settings. Please refer to the specifications section of this
manual for specific input, output and other figures.
AC Power
Your CLX-52 equalizer should be connected to a standard 3-wire grounded electrical
outlet supplying 100-240 Volts, 50-60 Hz. To reduce the risk of ground loop hum, connect
all audio equipment to the same electrical power source. Removal of the ground pin is both
unlawful and dangerous, as a potential shock hazard could result.
This unit will perform normally within the AC voltage range specified above. Voltages
less than this, as found in “brown-out” conditions, may reduce performance. In the event of
a blown fuse, replace only with same type fuse. No user serviceable parts are inside the
chassis. Overall power consumption is less than 5 watts.
NOTE: The power switch does NOT isolate the appliance from mains. Make sure the mains
power socket or an alternative disconnect device is near by and easily accessible. When the
product is connected to mains, the line-filter and the input of the fuse are energized.
Safety Instructions – 3
Introduction - 4
CLX-52 – 5
Connectors & Cables – 5
Physical Description - 6
Front Panel
Rear Panel
Installation – 7
General Requirements
AC Power
Typical Applications - 8
Troubleshooting - 9
Dimensions - 9
Specifications - 10
Warranty - 11