4. Set the minimal divergence of the illuminator
channel.
5. Superpose centers of the spots produced by the aimer
and illuminator on the aiming mark by rotating
adjustment knobs (1, Fig. 1), (17, Fig. 2).
6. Fire the weapon.
7. If point of impact is off the aiming mark adjust
windage and elevation by rotating adjustment knobs
(1, Fig. 1), (2, Fig. 1), (17, Fig. 2). (Each click of
adjustment mechanisms shifts radiation spot by 5 cm
on the target at 100 m.)
8. Repeat steps 7 and 8 until point of impact coincides
with the aiming mark.
When adjusted unit is remounted on the same Picatinny
rail of the same weapon no re-adjustment is required.
Aiming
When firing at a distance of up to 200 m the radiation spot
is to be aimed at the target.
When firing at a longer distance elevation adjustment may
be required.