7.20 System log
Group: syslog
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enableremotelog <boolean> 0 6/6 Enable remote log.
serverip <IP address> <blank> 6/6 Log server IP address.
serverport 514,
1025~65535
514 6/6 Server port used for log.
level 0~7 6 6/6 Levels used to distinguish the
importance of the information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
setparamlevel 0~2 0 6/6 Show log of parameter setting.
0: disable
1: Show log of parameter setting
set from external.
2. Show log of parameter setting
set from external and internal.
7.21 UART control
Group: uart (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] <blank> 1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128] <blank> 1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 0 1/4 Enable HTTP tunnel channel to
control UART.